The basic properties for an error end event are:
| Property | Required | Description |
|---|---|---|
| ID | Required | A unique identifier for the end event. This value is system-generated and cannot be changed. For example: EndEvent_00ln22h. |
| Name | Optional | The label displayed on the process diagram. Use a clear, business-focused name to describe why the process ends at this point. |
| Documentation | Optional | A free-text description explaining what happens when the process reaches this end event. Use this field to provide helpful context for other users. |
| Asynchronous Continuation | Optional |
When an end event is configured with asynchronous continuation, the process action is executed immediately, but the execution does not continue in the same request or thread. This creates a breakpoint in execution and separates process instantiation from further processing. It helps avoid long-running synchronous operations and improves reliability by ensuring that the initial process state is saved before execution continues. |
In addition to the basic end event properties, the generic Error End Event has the following properties:
| Property | Description |
|---|---|
| Error |
An error needs to be defined for the error end event to catch. A previously created Error can be selected from the drop-down list in its properties, or a new one created using the + symbol. An Error name and Error code can then be set. To create a new error use the + symbol against an error event such as an end error event, or make sure no BPMN element is selected by clicking on a blank section of the process canvas and the Edit Errors button will be visible in the right-hand properties panel. |