A Terminate End Event is used to immediately stop the execution of a process or sub-process.

Use a terminate end event when the process must stop immediately, without waiting for other paths or activities to complete.

This event is especially useful in scenarios where continuing execution is unnecessary or could lead to incorrect results. Use it when:

  • A process reaches a final condition that makes all other work irrelevant.
  • One path in a parallel flow determines the overall outcome and the remaining paths should be canceled.
  • A critical condition requires an immediate stop to prevent further processing.
  • You want to end a process as soon as a specific result is reached (for example, a “winner” in a parallel decision or race).

When a terminate end event is triggered:

  • All active elements in the same process scope are stopped.
  • Any parallel paths are canceled immediately.
  • The process (or sub-process) ends without completing remaining work.

A terminate end event affects only its current scope. For example, if used inside a sub-process, it ends that sub-process but does not affect the parent process.