Don't Map Variables - Don't Map Variables - Content Innovation Cloud - Hyland Automate Modeler - Current/Hyland-Automate-Modeler/yog1674557106006 - Current - Current

Hyland Automate Modeler

Platform
Content Innovation Cloud
Product
Hyland Automate Modeler
Release
Current
License
ft:lastPublication
2026-11-02T23:02:36.222215
ft:locale
en-US

The Don’t map variables option disables data exchange between a BPMN element and other models in the process. When Don’t map variables is selected, input or output mapping isn't applied and the element operates without receiving or updating process variables.

Don’t map variables is the default behavior.

Use this option in the following scenarios:

  • The element does not require any process data
  • Data exchange is handled through another mechanism (for example, static configuration or internal logic)
  • You want to restrict data flow for clarity, security, or performance reasons

For example, if Don’t map variables is selected for a user task in a process then none of the form fields will be populated with values from earlier within the process instance. Similarly, when the form is completed, none of the values entered by the user can be reused later in the process, such as within a decision table.