Issue: When starting the Hyland RPA Conductor service, the error 1053 appears.
Solution
- Navigate to Installation folder\Hyland RPA Conductor\Plugins.
- Delete the file config.xml.
- Open a PowerShell window with Administrator rights.
- Navigate to Installation folder\Hyland RPA Conductor.
-
Execute the following command:
Get-ChildItem -Path . -Recurse | Unblock-File
- Launch Hyland RPA Conductor.
Issue: A task has failed and the remark in RPA Web Manager is: Bit block transfer failed code: 5
Solution: Check the maximum runtime for the process in RPA Web Manager. If the process exceeds this time, Hyland RPA Conductor will stop it.
Issue: Service does not start with signed assemblies.
Solution: In some rare cases, our signed assemblies are blocked due to Firewall restrictions and therefore the service is unable to start without any detailed exception. In this case, it would be required to either unblock the required URLs used by the Certificate authorities or to adjust the Conductor.exe.config to allow the service to start.
Conductor config:
<configuration>
<runtime>
<generatePublisherEvidenceenabled="false"/>
</runtime>
</configuration>
Firewall restrictions:
crl.globalsign.com. CNAME 21600 global.prd.cdn.globalsign.com. global.prd.cdn.globalsign.com. CNAME 900 cdn.globalsigncdn.com.cdn.cloudflare.net. cdn.globalsigncdn.com.cdn.cloudflare.net. A 300 104.18.21.226 cdn.globalsigncdn.com.cdn.cloudflare.net. A 300 104.18.20.226 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ tl.symcb.com. CNAME 300 crl-symcprod.digicert.com. crl-symcprod.digicert.com. CNAME 3600 cs9.wac.phicdn.net. cs9.wac.phicdn.net. A 3600 93.184.220.29