Installing the Test System Creation utility involves running the associated setup.exe installer file and configuring connection strings for both the source and the test databases. The connection strings may be configured just after running the installer or by editing the tsc.exe.config file.
To install the Test System Creation utility:
-
Launch the Test System Creation installer by executing the
setup.exe file associated with the Test System Creation
utility.
By default, the setup.exe file associated with the Test System Creation utility is located in the \Install\Test System Creation folder of your source installation files.The welcome page of the installation wizard is displayed.
-
Click Next.
The Destination Folder page is displayed.
-
Optional: Change the destination folder by doing one of the following:
- Enter the top-level installation directory in the text field and proceed to step 4.
- Click Change to browse to the file location.
By default, the destination folder location is C:\Program Files (86x)\Hyland\.
Note:This location does not affect components not installed under the top-level directory. If the installer provides for the installation of multiple components, the specific installation locations of each component can be changed later in the installation process.
If Change is clicked, the Change destination folder dialog box is displayed.
or select it from the Look in drop-down list, then click OK.
-
Set a destination folder by doing one of the following:
- Enter a folder name in the Folder name field.
- From the Look in drop-down menu, select the folder where you would like to store the installation files.
- Click OK.
The Destination Folder page is displayed, and the new destination folder appears in the text field. -
Click Next.
The Ready to install page is displayed.
-
Click Install.
After installation has completed, the Completed page is displayed.
-
Optional: Select Launch Web Application Management
Console to open the Web Application Management Console and
configure the connection strings used to access the source and test
databases.
If this option is not selected, the connection strings can be configured by manually editing the Test System Creation configuration file. For more information, see Configuration.
Note:You must configure valid connection strings for both the source and the test databases in order for the Test System Creation utility to function properly.
-
Click Finish.
The tsc.exe executable and all required files are saved to the specified destination folder.
- If Launch Web Application Management Console was not selected, the installation is complete.
- If Launch Web Application Management Console was selected, the dialog box for editing the connection strings for tsc.exe.config is displayed.
-
To encrypt all connection strings configured in the application's .config file,
ensure the Options > Encrypt Connection Strings menu option is selected. This option is automatically selected by
default every time you open the connection strings dialog box, and the connection
strings are encrypted when the .config file is saved.
CAUTION:
It is strongly recommended to encrypt the connection strings. If they are not encrypted, all data source connection information is visible in the .config file and could expose sensitive data, including any entered database user names and passwords.
-
Click Add to create a new connection string.
The fields on the right become available for interaction.
-
Do one of the following depending on the purpose of the connection string being
created:
- If you are configuring Reporting Dashboards with a secondary connection string with a read-only database user account, select Options > Populate Read-Only User. This optional feature populates the User ID and Password fields with the credentials for the read-only user. For more information, see the Reporting Dashboards documentation.
- If you are creating a connection string for any other purpose, skip this step.
-
In the fields on the right, enter the following information about the data source:
Option
Description
Data Source Name
A unique name that you create to identify the connection string.
Note:This identifying name may be different from the name of the actual database.
Data Provider
The data provider type used for the database. Select one of the following:
-
System.Data.SqlClient: Select this for a SQL Server database.
-
Oracle.ManagedDataAccess.Client: Select this for an Oracle database.
Note:Only SQL Server and Oracle data providers can be used to connect to the OnBase database.
-
-
Depending on your selection for Data Provider in the previous step, enter the following database connection information:
-
If System.Data.SqlClient is selected (for a SQL Server database):
System.Data.SqlClient Option
Description
Data Source
Enter the server\instance name of the SQL Server instance hosting the database.
Database
Enter the name of the SQL Server database.
-
If Oracle.ManagedDataAccess.Client is selected (for an Oracle database):
Oracle.ManagedDataAccess.Client Option
Description
TNS Connection String
Select this option to enter a full TNS connection string to connect to the Oracle database. Deselect the option to use the connection name instead.
Note:Selecting this option enables the Host, Database, Protocol, and Port fields for interaction.
Data Source
Enter the TNS name or connect descriptor of the Oracle database.
Note:This field is available only if the TNS Connection String option is deselected.
Host
Enter the host address of the Oracle database.
Database
Enter the name of the Oracle database.
Protocol
Select the protocol to use for connecting to the Oracle database. Options are:
-
TCP
-
TCPS
Port
Enter the port to use for connecting to the Oracle database.
-
-
-
Select one of the following options from the Encrypt
drop-down list to configure the encryption settings for your connection
string:
Option Description Strict Do not select this option. This option is not supported. Mandatory Select this option to only allow encrypted connections. Note: When using a SQL Server database, you must ensure your database is configured with a certificate to support encryption.Optional Select this option to allow unencrypted connections or defer encryption requirements to the database server. When using a SQL Server database, note the following information:
-
ADO.NET connection strings for Microsoft SQL Server databases enforce encryption by default unless otherwise specified in your connection strings.
-
You must ensure the encryption settings for both your SQL Server database and your ADO.NET connection strings are compatible.
-
For more information on configuring Microsoft SQL Server for encryption, see the Microsoft article Configure SQL Server Database Engine for encrypting connections available at https://learn.microsoft.com.
-
-
Enter the following security information:
Option
Description
Integrated Security
Select this option to use Windows Authentication to connect to the database.
CAUTION:It is strongly recommended to use Windows Authentication (referred to as integrated security) instead of a database account for authentication. To use Windows Authentication, the Windows identity running the process must be able to connect to the database. This user must also be configured with the configgp role in the database.
User ID
The user name of the database user account accessing the database.
Note:This user name is for a database user account, not a user account for OnBase.
Password
The password of the database user account accessing the database.
Note:This password is for a database user account, not a user account for OnBase.
-
Enter any additional options.
Option
Description
Additional Options
Any additional options for the connection string. For more information on available connection string options and syntax, see the documentation for your database provider (SQL Server or Oracle).
- Click Test Connection to test whether the entered information forms a valid connection string.
-
Click Create to save the information in the fields and
create the connection string.
The name of the data source is added to the Data Sources list on the left, and the connection string is displayed in the Connection String section.
- Add a second connection string for the source or the test database depending on which source was added previously.
- After adding both connection strings, select File > Save to save the tsc.exe.config file.
-
Select File > Close to exit the connection strings dialog box.
Note:
To ensure that the required system settings take effect, it is considered a best practice to restart the installing machine once the installer has finished.