QA Integrated Scans - QA Integrated Scans - When an integrated scans document is imported into OnBase, it is immediately added to the Content Conditioning lifecycle. All previously described validation logic is executed against the document to validate that OnBase received valid keyword metadata from the EMR. After that logic is complete, the document reaches the QA Review of Integrated Scans Task List (if enabled). - OnBase - Other - Content Conditioning - Other/Content-Conditioning/2.2/Content-Conditioning/Appendix-Technical-Design/QA-Integrated-Scans - 2.2 - 2.2

Content Conditioning

Platform
Other
Product
Content Conditioning
Release
2.2
License
ft:lastPublication
2024-11-20T20:06:20.741000
ft:locale
en-US

When an integrated scans document is imported into OnBase, it is immediately added to the Content Conditioning lifecycle. All previously described validation logic is executed against the document to validate that OnBase received valid keyword metadata from the EMR. After that logic is complete, the document reaches the QA Review of Integrated Scans Task List (if enabled).

The QA Integrated Scans logic can be enabled or disabled as desired. When the integrated scans document enters the task list the first step is to determine if the document has gone through the logic before. If this is the document’s first time through, a Shadow eForm is created and specific visit and patient indexing values from the main document are copied to the Shadow eForm. This Shadow eForm is a record of the keywords and the document type as it was originally indexed. A note is added to the document to give the end users a visual indication that the document still needs to undergo QA Review. Deficiencies should not be added to these documents until QA Review has been completed. The document is then sent to a CPD Capture Process to the Awaiting QA Review step.

Once the document has completed QA Review, it is sent back to Content Conditioning. All of the Content Conditioning pre-tasks are re-triggered to validate the indexing values again. When the document reaches the QA Integrated Scans logic for the second time, all the indexing values on the primary document are compared against the values on the previously created Shadow eForm. If the values match this means that the document has not changed during the QA Review. Thus, the document is simply removed from the lifecycle.

If the values do not match, this implies that the document was changed during the QA Review. Thus, an MDM^T11 is sent to the EMR (using the shadow document) to remove the old link and a new MDM^T02 is sent to recreate the link with the updated indexing values. After this point the document is removed from the lifecycle.

Note: Do not use the Data Capture Server to perform barcoding in the capture process with QA of Integrated Scans. DCS creates a new document and document handle when processing bar codes and does not work with the shadow document and solution.