A few conditions may prevent the Class Group Settings page from loading successfully. The following are some common issues and steps to correct.

Slow Network Conditions

The Class Group Settings page connects to OnBase using Content Federation Services (CFS). Depending on network conditions it might take a while to load as the connection is established.

Refresh the browser window to reload the page. If the Class Group Settings page doesn’t load after 60 seconds, try clicking off to another page and then back to refresh the screen. Wait another 60 seconds. If the page is still not loading, continue troubleshooting.

Check the AutoFill Lookup Process

  1. Open the Process Instances page in Studio Admin.
  2. Select the Intelligent MedRecords (IMR) application from the Application Name filter button.
  3. Look for a row where the Process Definition Name is autofill-lookup and the Start Date aligns with when the page wouldn’t load.
    • If the row doesn't exist, see Check for Console Errors.

      If the row does exist, click the vertical ellipsis menu associated with that row, and select Service Tasks.

  4. On the Service Tasks page, find the row where the Activity Name is Autofill Search and the Start Date aligns with when the page wouldn’t load
  5. Check the status of the task.
    • Completed means the task successfully loaded. Go back to the Class Group Settings page. If it isn’t populated, then see Check for Console Errors.
    • Running means the task is still running. Wait 60 seconds, and then refresh the Service Tasks page and check the status.
    • Error means there was an error. View the error to determine your next steps. Refer to Known Connection Issues to determine the appropriate action.

Check for Console Errors

  1. With the Class Group Settings page open, press the F12 key.
    If your browser prompts you to confirm that you want to open developer tools, click Yes.
    The browser's developer tools (or DevTools) window is displayed.
  2. Refresh the Class Group Settings page.
  3. Check the developer tools Console tab for errors.

    If the following error is displayed, then a field mapping may need to be updated:

    TypeError: Cannot read properties of undefined (reading 'sourceObjectId')

    For information on updating field mappings, see Updating Class Fields.