Perceptive Content uses connection strings with default properties set. The following is a detailed list of properties that is set for each database configuration.
DataDirect Oracle connection properties
For more information, about these settings, see the Progress DataDirect for ODBC Oracle Wire Protocol Driver manual. The provided defaults should be sufficient for most installations.
| Property Name | Default Value | Configurable inow.ini ODBC Setting |
|---|---|---|
| DSN | odbc.dsn | |
| UID | inuser | odbc.user.id |
| Password | odbc.user.password | |
| StaticCursorLongColBuffLen | 131072 | odbc.max.long.varchar.column.size |
| IANAAppCodePage | 2252 |
Native Oracle connection properties
For more information, about these settings, see the "Format of the Connection String for the SQLDriverConnect Function" section in Oracle's Using Oracle ODBC Driver reference document.
| Property Name | Default Value | Configurable inow.ini ODBC Setting |
|---|---|---|
| DSN | odbc.dsn | |
| UID | inuser | odbc.user.id |
| PWD | odbc.user.password | |
| FWC | F | |
| QTO | T | |
| DBA | W | |
| APA | T | |
| ODA | T |
Native Microsoft SQL Server connection properties
For information, see the Microsoft ConnectionString documentation.
| Property Name | Default Value | Configurable inow.ini ODBC Setting |
|---|---|---|
| DSN | odbc.dsn | |
| UID | inuser | odbc.user.id |
| PWD | odbc.user.password | |
| APP | Current App Name | |
| Trusted_Connection | no | |
| AutoTranslate | no | |
| Regional | no |
Native PostgreSQL connection properties
For more information, see the PostgreSQL libpq-connect documentation.
| DSN | odbc.dsn | |
|---|---|---|
| UID | inuser | odbc.user.id |
| PWD | odbc.user.password | |
| Protocol | 7.4-2 | |
| UserServerSidePrepare | 1 | |
| UniqueIndex | 1 | |
| MaxVarcharSize | 2048 | odbc.max.char.column.size |
| UnknownSizes | 0 | |
| UnknownAsLongVarchar | 0 | |
| ByteaAsLongVarBinary | 1 | |
| ReadOnly | 0 | |
| BI | -5 | |
| AB | 0x0 | |
| UserDeclareFetch | 0 | |
| LFConversion | 0 |